Skip to content
Skip to documentation content
Browse documentation

Multi-node inference

A model that does not fit one node can still be one InferenceService. spec.multiNode names the nodes, the operator runs one runtime process on each, and the processes cooperate over the fabric between them as a single serving group. Rank 0 answers requests; the other ranks are headless workers.

This is the shape for a DGX Spark ring, for a pair of DGX B200 chassis, and for any cluster where the weights only fit across machines. It is not a replacement for tensor parallel inside one chassis: a model that fits eight GPUs on one node stays a single pod with tensorParallelSize: 8.

Supported runtime in this release: vLLM.

The spec

apiVersion: inference.llmkube.dev/v1alpha1
kind: InferenceService
metadata:
  name: dsv4-vision-ring
spec:
  modelRef: deepseek-v4-flash-vision-exp
  runtime: vllm
  image: vllm/vllm-openai:deepseekv4-flash-vision-arm64-cu130
  resources: {gpu: 1, memory: 110Gi, cpu: "8"}   # per member
  vllmConfig:
    tensorParallelSize: 2
    enableExpertParallel: true
    kvCacheDtype: fp8_e4m3
    maxModelLen: 262144
  multiNode:
    rdmaResource: rdma/rdma_shared_device_a
    ibGIDIndex: 3
    members:
      - node: ahazidgx3
        fabric: {address: 10.10.4.1, socketInterface: enp1s0f0np0, ibHCA: rocep1s0f0}
        modelCache: {claimName: dsv4-vision-dgx3}
      - node: ahazidgx1
        fabric: {address: 10.10.4.2, socketInterface: enp1s0f1np1, ibHCA: rocep1s0f1}
        modelCache: {claimName: dsv4-vision-dgx1}

members is the rank order. The first entry is rank 0: it serves the endpoint, keeps the labels the Service and the PodMonitor select on, and carries the probes. Every other member runs --headless and joins the torch.distributed rendezvous at rank 0’s fabric address.

resources is per member. The world size is tensorParallelSize x pipelineParallelSize and must equal members x resources.gpu: every GPU in the group is a rank. Leave both sizes unset and the operator derives tensor parallel across the whole group.

Why fabric settings are per member

On a point-to-point ring every leg is its own subnet, and the same physical cable has a different interface name and RDMA device name at each end. So the NIC that carries the bootstrap sockets and the HCA that NCCL should use are properties of the member, not of the service:

FieldBecomesNotes
fabric.addressVLLM_HOST_IP, and --master-addr for everyone when on rank 0required on rank 0
fabric.socketInterfaceNCCL_SOCKET_IFNAME, GLOO_SOCKET_IFNAME, TP_SOCKET_IFNAMEbootstrap only; data goes over RDMA
fabric.ibHCANCCL_IB_HCAexact device (rocep1s0f0) or prefix (mlx5)
ibGIDIndexNCCL_IB_GID_INDEX on every member3 is RoCE v2 on ConnectX-7
rendezvousPort--master-portdefault 29500

User env on the service is applied after these, so an override still wins.

RDMA prerequisites

NCCL over RoCE or InfiniBand from an unprivileged pod needs two things: a device plugin that advertises the HCA as an extended resource, and CAP_IPC_LOCK so NCCL can pin registered memory. Set rdmaResource to the plugin’s resource name and the operator requests one per member and adds the capability. Members run with hostNetwork and hostIPC.

Check the head’s log after startup. This line means RDMA is in use:

NCCL INFO NET/IB : Using [0]rocep1s0f0:1/RoCE

NET/Socket instead means NCCL fell back to TCP. It works, but on the Spark ring prefill drops about 2.7x. Fix the resource, the capability, or the GID index before benchmarking anything. NCCL prints that line only at NCCL_DEBUG=INFO; at WARN the log is silent about the transport, so set INFO for the first start and drop it afterwards.

Storage

Every member needs the weights on its node. With a ReadWriteMany class, spec.modelCache.claimName alone serves all members. Without one, give each member its own claim through members[i].modelCache.claimName; the claim replaces the service claim in that member’s pod. All claims are user-owned and must exist before the service is created; a missing one fails the service with a message naming the member.

The operator swaps only the claim name, never the path, so the Model’s path inside the claim must be identical on every member. Two things bite here. Weights staged by the Hugging Face hub live under models--<org>--<name>/snapshots/<hash>/, where every file is a relative symlink into ../../blobs/; a volume rooted at the snapshot directory mounts none of those targets and vLLM reports no configuration file. Root the volume at the models--<org>--<name> directory and use pvc://<claim>/snapshots/<hash> as the Model source. And a node that holds a plain directory needs the same relative path, which a relative symlink inside the volume root provides (snapshots/<hash> -> ../<dir>); a symlink to a path outside the volume root dangles the same way.

Failure semantics

The group is Ready only when every member is Running and rank 0 passes its readiness probe. Any member that fails, restarts, is terminating, or carries a stale spec deletes the whole group, and the next reconcile recreates it. A rank 0 that stays Running but not Ready for 30 minutes counts as failed. There is no rolling replacement: the ranks share one process group, so a partial group cannot serve, and a recreate costs a full weight load on every member (two to eight minutes measured on the Spark ring).

Any change to spec.multiNode, the model, the image, or the runtime config recreates the group as well. replicas must be 1 or unset; autoscaling does not apply.

Status shows each rank:

status:
  multiNode:
    size: 2
    readyMembers: 2
    members:
      - {rank: 0, node: ahazidgx3, pod: dsv4-vision-ring-mn-0, phase: Running, ready: true}
      - {rank: 1, node: ahazidgx1, pod: dsv4-vision-ring-mn-1, phase: Running}
  conditions:
    - type: MultiNodeGroupReady
      status: "True"
      reason: AllMembersRunning

Member pods are named <service>-mn-<rank> and carry the labels inference.llmkube.dev/multinode-group and inference.llmkube.dev/multinode-rank.

Measured configurations

Two DGX Sparks (GB10, 121 GiB usable each) over one ConnectX-7 RoCE leg, 2026-09-02, single-stream agentic prompts:

ModelTopologyPrefill tok/sDecode tok/s
DeepSeek-V4-Flash-Vision-Exp (MXFP4)vLLM TP2 + expert parallel2,08924.0
DeepSeek-V4-Flash-Vision-Exp, DSpark draft k=3vLLM TP2 + expert parallel2,04739.1
Qwen3.8-Flash-Next (NVFP4), MTP k=3vLLM TP2 + expert parallel2,78948.1
DeepSeek-V4-Flash (MXFP4)llama.cpp RPC, two nodes35719.4

The same model as an operator-managed multiNode group, benchmarked from inside the cluster (median of three 3.7k-token prompts, then one 26k-token prompt):

Group configurationPrefill tok/s (3.7k / 26k)Decode tok/s (3.7k / 26k)KV cache tokens
vLLM TP2 + expert parallel1,870 / 1,91525.3 / 25.01,768,361
plus DSpark draft k=31,820 / 1,88837.0 / 39.41,132,222
plus DSpark and maxNumBatchedTokens: 81922,107 / 1,98537.3 / 38.0333,071

Two things to take from that table. The draft is where the win is for a single agentic stream: decode rises by half for a third of the KV cache. And the prefill chunk size is a trade, not a free setting: 8192-token chunks match the hand-tuned prefill number but cost another 800k tokens of cache, which decides how many long-context requests can run at once. The group recreates in four to five minutes when a member dies, measured by deleting the worker pod by hand.

Cross-node tensor parallel beat pipeline parallel on decode and tied it on prefill; both models refuse pipeline parallel anyway. Three nodes did not help single-stream latency: the third node adds a hop without adding work per token.

For a pair of DGX B200 chassis the same spec reads tensorParallelSize: 8, pipelineParallelSize: 2, two members with ibHCA: mlx5 and resources: {gpu: 8}.

Three-Spark ring

Three DGX Sparks cabled directly (Port0 of each to Port1 of the next, NVIDIA’s connect-three-sparks playbook) form three point-to-point legs and no switch. Its default leg addresses sit in 192.168.0.0/24 to 192.168.5.0/24; if the management LAN is 192.168.1.0/24, as in the sample, move the legs elsewhere (this lab uses 10.10.0.0/30 to 10.10.5.0/30) before the bootstrap can even start. That changes two things about spec.multiNode that the field comments state too gently.

fabric.address is the bootstrap plane, and on a ring no fabric address will do. Rank 0’s address is what every other rank dials for the torch rendezvous, and each rank’s address becomes its VLLM_HOST_IP. On a ring each /30 is reachable from one neighbour only, so use the management IP and name the management NIC in socketInterface. Bandwidth is irrelevant here; the bootstrap is a handful of small messages.

ibHCA is the data plane and takes a comma list. List every ConnectX port on the member (a Spark has four, named rocep1s0f0, rocep1s0f1, roceP2p1s0f0 and roceP2p1s0f1: two ConnectX controllers with two ports each) and set NCCL_IB_SUBNET_AWARE_ROUTING=1 in spec.env. NCCL >= 2.30 then picks, per peer, the local port whose subnet matches that peer’s. Without it NCCL assigns the NIC by channel index on both ends of every link, and a P0->P1 ring is an odd cycle that no index assignment can satisfy: every channel is wrong on one end and the group dies with ncclSystemError during channel setup. NCCL_IB_MERGE_NICS=0 and NCCL_NET_PLUGIN=none complete NVIDIA’s ring environment; do not set NCCL_IB_ADDR_RANGE or NCCL_CROSS_NIC.

Measured 2026-09-13 with a 256 MB all-reduce over three ranks: 23.2 GB/s bus bandwidth on the ring (11.3 GB/s for two ranks on one leg; 7.9 GB/s with NCCL’s Socket transport routed over the same legs, the fallback if RDMA is unavailable). The full serving example, DeepSeek-V4.1-Flash EXL3 3.5bpw at TP3, is config/samples/inferenceservice_multinode_vllm_three_sparks_ring.yaml, with its Model and the two checkpoint-side Jobs (the TP3 config.json edit, and a page-cache drop before the group boots) next to it. Text-only, single stream, on that ring: prefill 1,094 to 1,334 tok/s from 3.4k to 49.8k prompt tokens, decode 26.5 tok/s without speculative decoding and 31 to 35 tok/s with DSpark k=5 (65 tok/s on code, 1.5x across a mixed set; block verification is lossless). The sample runs DSpark k=5 with a 131,072-token context and four sequences, which leaves a KV pool of about 356,000 tokens at gpuMemoryUtilization: 0.78.

Five operational notes from bringing it up: every member needs all 54 checkpoint files locally, including the two 101 GB Engram tables the runtime reads from NVMe; a claim the operator must stage into has to be a pre-bound static local PV (the members are placed with nodeName, so a WaitForFirstConsumer class never binds); and after a large stage, drop the page cache on each member before creating the InferenceService, or the worker refuses to start with CUDA-free below gpuMemoryUtilization x total. Turn swap off on every member first (sudo swapoff -a): an overrun then OOM-kills the worker, which the operator restarts, where a swapping node pages kubelet out and needs a power cycle; and use an image that pre-warms its JIT kernels, because compiling a cutlass GEMM on the serving node costs about 6 GB of host RAM per nvcc process on top of 79.5 GiB of pinned weights.

Limits in this release

  • vLLM only. llama.cpp RPC members are the next runtime; the manual pattern is in the two-Spark runbook until then.
  • One group per service; no autoscaling; recreate is the only update strategy.
  • Members take an existing claim; the operator does not stage weights per member yet.
  • The stock DeepSeek-V4-Flash-Vision image needs a FlashInfer prefill patch on GB10 until it ships upstream; the LLMKube runtimes image carries it.